{"product_id":"incubator-analyzer-co2-o2-usa-nist-calibration","title":"Incubator Analyzer CO2 \u0026 O2 | USA NIST Calibration","description":"\u003ch2 class=\"product-meta__title heading h1\"\u003eIncubator Analyzer CO2 \u0026amp; O2 | USA NIST Calibration\u003c\/h2\u003e\n\u003ch3\u003eFeatures: \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eINCUBATOR ANALYZER:\u003c\/strong\u003e\u003cspan\u003e CO2 (NDIR sensor) and O2 (electrochemical sensor) incubator analyzer. Comes FACTORY-CALIBRATED. Turn ON and GO.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eCOLOR:\u003c\/strong\u003e\u003cspan\u003e Color screen and graph functions allow for intuitive operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eDATA LOGGING:\u003c\/strong\u003e\u003cspan\u003e USB recharging and real-time computer data acquisition. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eSTRONG:\u003c\/strong\u003e\u003cspan\u003e Robust design constructed with high-strength ABS and anti-slip grip rubber. Water-resistant, dust-proof, and explosion-proof.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eTRUSTWORTHY:\u003c\/strong\u003e\u003cspan\u003e ** 1-year limited warranty ** Arrives with USA NIST calibration certificates ** Product tested and verified in the USA ** \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003cspan\u003e Our incubator analyzer detects CO2 and O2 gas and is the perfect solution to an easy-to-use incubator analyzer for incubator gas level verification.\u003c\/span\u003e\u003cspan\u003e This unit will verify the O2 and CO2 levels in your incubator to make sure your incubator is operating to specifications. Based on our industrial analyzer platform, this analyzer includes a built-in pump that is easy to use and very portable. Insert the tube into your incubator sample port and the other end into the analyzer. Within 60 seconds, you will be able to determine the levels of O2 and CO2 in your incubator. Comes with a color screen, large digits, and on-screen real-time graphing. The detector is constructed with an advanced electrochemical oxygen sensor. The internal 32-bit microprocessor allows for user calibration, ON\/OFF flow, and test control. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhich CO2 Gas Monitor shall I purchase for my incubator?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIt all depends on your incubator. For example: \u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIf your incubator has a sample air port, this is the best. Y\u003cspan\u003eou must sample the air from the air port (usually a barb port 1\/4 or 1\/8 inch is provided). Confirm that air is under positive pressure and the air is being expelled by the port. If the incubator is pressurized and air flows out of the port, the \u003cmeta charset=\"utf-8\"\u003eFD-90A-CO2 (10%) \u003c\/span\u003e\u003cspan\u003ewith work and will be the best. Run a tube from the incubator sample port to the gas calibration cap and attach the cap to the \u003c\/span\u003e\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003eFD-90A-CO2 (10%)\u003c\/span\u003e\u003cspan\u003e. When testing CO2, ensure the incubator humidity is as low as possible (to reduce cross interference with CO2 error) and set the temperature to 70F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIf the incubator is not pressurized, and no air is being expelled from the air nipple or barb, then you need the FD-600-CO2 or FD-600-CO2-O2-INC (with oxygen). This analyzer has a built in pump and will draw the air from the incubator to the analyzer. When testing CO2, ensure the incubator humidity is as low as possible (to reduce cross interference with CO2 error) and set the temperature to 70F.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLastly, if your incubator has a glass window door, you can use the\u003cspan\u003e FD-90A-CO2 (10%)\u003c\/span\u003e, and place the CO2 monitor in the incubator.\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eWhen testing CO2, \u003c\/span\u003e\u003cspan\u003ee\u003c\/span\u003e\u003cspan\u003ensure the incubator humidity is as low as possible (to reduce cross interference with CO2 error) and set the temperature to 70F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003cspan\u003e Incubator analyzer and magnet back, English user manual, USA NIST calibration certificate, USB charging cable, Tube and Barb Coupler,\u003c\/span\u003e\u003cspan\u003e charger, and tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"482\" height=\"269\" src=\"https:\/\/www.youtube.com\/embed\/Z9YbOtL9BFw\" title=\"CO2 and O2 Analyzer for Incubators (FD-600-CO2-O2-INC)\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications: \u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOxygen (O2) Detection\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e0 - 30% with 0.01% resolution (electrochemical sensor cell)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eCarbon Dioxide (CO2) Detection\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e0 - 10% with 0.01% resolution (NDIR sensor)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eError\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e≤ ± 3% F.S.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eResponse Time\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e≤ 60 sec \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eStore \/ Operating Temp\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e0°F - 122°F\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eStore \/ Operating Humidity\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e\u0026lt;95%RH\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eGas Sensor Life\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e2 - 3 years (O2 sensor), \u0026gt; 5 years (CO2 sensor)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eCalibration Location\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLos Angeles, California, USA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eCalibration Standard\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eUSA NIST traceable reference gas\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eRecommended Calibration Period\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e12 months\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eExplosion-Proof Grade\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eEx ib IIB T4 Gb\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eProtection Grade\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eIP65\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eWeight\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e14 oz\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eDimensions\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e5.1 in × 2.6 in x 1.2 in\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eCharge Time\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e4 hours\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eOperating Time\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e\u0026gt; 10 hours\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003ePump Rate\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e0.1 LPM - 0.3 LPM (100 - 300 cc\/min)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.8104%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eAlarm\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 65.8318%;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eLED, Buzzer, and Vibration\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Forensics Detectors","offers":[{"title":"1 EA","offer_id":51789985218926,"sku":"FD-600-CO2-O2-INC","price":1295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0593\/5025\/3722\/files\/FD-600-CO2-O2-INC-Photo1.jpg?v=1738087321","url":"https:\/\/animal.ivfstore.com\/es\/products\/incubator-analyzer-co2-o2-usa-nist-calibration","provider":"Animal IVF Store","version":"1.0","type":"link"}